Fit endstops capable of stopping the gate at rated speed
Make H>h to ensure gate will not jump over endstop as shown
above
Ø16mm
h
H
Endstop
Endstop
Endstops
1
6
7
10
11
1. D5-Evo controller
2. Courtesy light fuse
(3A F/B)
3. Gate mounted origin
marker
4. Origin marker bracket
5. Origin sensor
6. Side covers
7.
8.
9. 1 x 12V 7.2Ah battery
10. Switch Mode 2A charger
11. Manual release access
door
Foundation plate
Motor fuse (30A ATO)
6. D5-Evo identification
2
3
4
5
8
9
3. Icons used in this guide
2. Important Safety Instructions
This guide is designed specifically for installers who are familiar with
the installation of standard sliding gate motors, but do not know the
specifics of the D5-Evo.
The D5-Evo is a domestic and light-industrial operator designed to
open and close sliding gates weighing up to 500kg. A custom designed
gearbox moulded from robust engineering polymers, coupled to a
powerful 12V DC motor, provides fast and reliable automation for
entrances to homes and small housing estates.
Please do not proceed with the installation until you have
read and fully understand the Safety Instructions
included in your product packaging
The Safety Instructions are also available on
www.centsys.com.au
1. Introduction
4. General description
This icon denotes variations and other aspects that should be
considered during installation
This icon indicates tips and other information that could be
useful during the installation
This icon indicates warning, caution or attention!
Please take special note of critical aspects that MUST be
adhered to in order to prevent injury
7. Preparation of site
General considerations for the installation
For comprehensive information, please refer to the full installation
manual available for download on www.centsys.com.au
Install the gate operator only if:
&
It will not pose a hazard to the public
&
There is sufficient clearance to a roadway and/or public
thoroughfares
&
The installation will meet all municipal and/or local authority
requirements once completed
&
The gate mass, length and application is within the operator
specifications
&
The gate is in good working order, meaning:
&
That it moves freely
&
Does not move on its own if left in any position
&
It can be installed to have sufficient clearance between
moving parts when opening and closing to reduce the risk of
personal injury and entrapment
&
Pushbuttons or keyswitches, when required, can be positioned
so that the gate is in line of sight of the operator
Make sure the gate mass,
starting - and rated-pull-force
limitations are not exceeded.
Guide-rollers must ensure that
the gate is held vertically through
the entire length of the gate
travel. For improved safety fit
additional support posts to
prevent gate from falling over
if guide rollers fail.
Ensure that the gate
cannot be lifted off the
motor pinion with the
anti-lift bracket fitted
Pull scale
Guide-rollers
Additional
support post
GAP<5mm
GAP<5mm
GAP<5mm
GAP<5mm
Typical anti-lift
arrangements
9. Cabling requirements
1
6
5
7
8
8
3
4
4
It is a 12V DC battery operated unit with the following limitations:
Operator push force - starting 30kgf
Operator push force - rated 17kgf
Gate mass – maximum 500kg
Gate length – maximum 100m
Maximum numbers of operations per day 150
5. Technical specifications
8. Lubrication
1. Lift the cover of the
operator.
2. Remove the battery so that
you can gain access to the
coloured filler plug.
3. Remove the coloured oil filler
plug by levering it out with a
screwdriver.
4. Empty the contents of the oil
bottle into the gearbox
(80ml).
5. Refit the coloured oil filler
cap.
Put 80ml oil
in here
Oil specificationsCEN
product code:
OIL80ML0X0/H
Castrol SAF-XO 75w-90
Synthetic Final Drive
Lubricant
Do not attempt to run the operator without first filling the
gearbox with lubricant
Legend
1. 220-240V AC mains cable via double pole mains isolator switch
2
(3 core LNE 1.5mm SWA)
Optional wiring (all cable is multi-stranded):
2
2. Intercom cable from motor to dwelling (n1 + 6 core 0.5mm )
2
3. Intercom cable from motor to entry panel (n2 0.5mm )
4. Safe Close and
Safe Open: Recommended infrared safety beams
2
(3 core 0.5mm )
2
5. Trg: Access control device (3 core 0.5mm )
6. Ped: Optional pedestrian keyswitch (a) OR keypad
2
(b) (3 core 0.5mm )
2
7. Trg: Optional external radio receiver (3 core 0.5mm )
8. Light: Optional pillar lights (3 core LNE SWA, size
according to power requirements)
n1 = number of cores required by intercom
n2 = number of cores required by intercom
Possibly increase cable thickness if pillar lights are installed
Type of cable must adhere to municipal bylaws but typically SWA
(steel wire armoured) cable is recommended. The armouring
provides excellent screening, which gives better protection against
lightning – earth one end of the screening)
Allows for all features such as pedestrian opening, status LED, etc.,
to be operated from the intercom handset inside the dwelling.
Number of cores and type of cable could vary depending on brand
of access control system being used
For optimum range, an external receiver can be mounted on the
wall
10. Manual operation
D5
D5D5
evo
evoevo
1. Insert the camlock key and
rotate it 90° clockwise.
This will allow for the removal
of the cover, as well as for the
rotation of the release
thumbwheel.
Do not remove the
thumbwheel. Removal of
the thumbwheel may
result in water entering
the gearbox and the
warrantee will be void
Disengage
gearbox/drive
D5
D5D5
evo
evoevo
D5
D5D5
evo
evoevo
1. Rotate thumbwheel anti-
clockwise until thumbwheel
feels loose in the hand. Make
sure that the manual
override access door can be
closed.
2. Slide gate until gearbox/drive
engages. Never run the
motor before the unit is
engaged.
Re-engage
gearbox/drive
Ensure that all the standard considerations for a quality
gate installation are adhered to as detailed in
CENTSYS' detailed installation manuals. These must
include:
11. D5-Evo operator installation
&
Correct access in and out of the premises
&
Endstops are mandatory and must be capable of stopping the
gate at rated speed
&
Guide-rollers and anti-lift brackets are correctly fitted
&
The gate mass, starting- and rated-pull-force limitations are not
exceeded
&
The D5-Evo is positioned correctly and does not protrude into the
driveway
2
Oil filling procedure
2. Rotate thumbwheel
clockwise until gearbox
releases and gate can be
moved manually.
3. If the gearbox must be left in
manual mode for an
extended period of time for
whatever reason, it is
recommended that the
access door is locked. This
secures the cover and
prevents access to the inside
of the unit, which contains
high voltages. It also
prevents theft of any
components and provides full
protection from the
elements.
B: Above pinion - Steel rack
* Includes 3mm clearance required
between rack and pinion
5
32 - 50
(Recommended to
allow for adjustment)
82
146*
Foundation
plate
Flat bar welded to
foundation plate and rail
1. To ensure operator does not
protrude into driveway, install
base plate at least flush with
the driveway entrance.
2. Determine a suitable position
and vertical height for the
operator by considering
Figures A, B and C.
A: Above pinion - Raz rack
5
32 - 50
(Recommended to
allow for adjustment)
82
163*
Foundation
plate
Flat bar welded to
foundation plate and rail
* Includes 3mm clearance required
between rack and pinion
Locate operator
position
D5
D5
Evo
EvoEvo
www.centsys.com.au
0.07.B.0009 D5-Evo Mechanical
Pocket Guide-5Jul2012
D5-Evo Pocket mechanical
installation guide
e
LIGHT-
INDUSTRIAL
SLIDING GATE
OPERATOR
TM
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - OPERATOR

Fit endstops capable of stopping the gate at rated speedMake H>h to ensure gate will not jump over endstop as shown aboveØ16mmhHEndstopEndstopEndst

Seite 2 - 13. Installation handover

Mounting the originmarker1. Close the gate completely.2. Mount the origin marker to the rack a minimum of 500mm from the origin sensor.3. For steel ra

Kommentare zu diesen Handbüchern

Keine Kommentare